Rat trachea cell
A rat trachea cell was observed by Scanning Ion Conductance Microscopy (SICM) which uses micro glass pipette to obtain very delicate samples such as cells, bacteria and etc. The scan image shows numerous beard-like structures of the rat trachea cell in liquid condition.
Scanning Conditions
- System: NX10
- Scan Mode: Scanning Ion Conductance Microscopy
- Scan Rate: 0.08 Hz
- Scan Size: 80 µm × 80 µm
- Pixel Size: 256 × 256 pixels
- Peak-to-valley: 11.3 µm
• Sample courtesy: Prof. Ushiki, Niigata University, Japan