ferromagnetic Vacuum Materials BlockCopolymer NCM Tape Nanotechnology molecule STM PolymerBlend GalliumPhosphide fluorocarbon Cobalt-dopedIronOxide DeflectionOptics Optic C_AFM Floppy HBN 3-hexylthiophene membrane Varistor India Hair ThermalDetectors TPU Nanostructure SelfAssembly Roughness OpticalModulator SFAs BCZT Copper Yeditepe_University PECurve medical
Report image
If you found this image unacceptable, please let us know. We will review your report and take action if we determine this image is really unacceptable.
ER 316L Stainless Steel
The ferrite MFM phase has a striped appearance due to its ferromagnetic behavior, while the paramagnetic austenite phase shows a uniform appearance.
Scanning Conditions
- System: NX20
- Scan Mode: AM-KPFM, MFM
- Cantilever: PPP-MFMR (k=2.8N/m, f=75kHz)
- Scan Size: 20μm×20μm
- Scan Rate: 0.3Hz
- Pixel Size: 512 × 512
- Lift height: 30nm
- Scan Mode: AM-KPFM, MFM
- Cantilever: PPP-MFMR (k=2.8N/m, f=75kHz)
- Scan Size: 20μm×20μm
- Scan Rate: 0.3Hz
- Pixel Size: 512 × 512
- Lift height: 30nm