How to choose an AFM probe
Contact Mode
For optimal performance with our AFM systems please request a quote from Park Systems. Mounted cantilevers are additionally tested. All probes that are not listed here from Adama Innovations, Applied Nano Structures, Inc, BudgetSensors, MikroMasch, Nanosensors™, Nanotools GmbH, Nanoworld AG, NuNano, Olympus Corp., are possible to order from our probe store. Probes from other manufacturers also can be possible to order upon request for quotation. The performance of probes ordered from other sources are not guaranteed.
Probe | Force Constant (N/m) | Frequency (kHz ) | Manufacture | Short Description | Quote | ||||||||||||||||||||||||||||||||||||||||||||||
PPP-CONTSCR | 0.2 | 25 | Nanosensors | ▪ Contact cantilever ▪ Backside reflex coating (Al) |
Request for Quote | ||||||||||||||||||||||||||||||||||||||||||||||
The NANOSENSORS™ PPP-CONTSCR is an alternative cantilever type for contact mode applications. The length of cantilever is reduced with respect to the preferred contact mode type enabling easier exchange with non-contact mode probes for some AFM instruments. Additionally, this probe type allows the application for lateral or friction force mode.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
NSC36/Al BS | 1 2 0.6 |
90 130 65 |
Mikromasch | ▪ Contact cantilever ▪ Backside reflex coating (Al) ▪ 3 cantilevers on a chip |
Request for Quote | ||||||||||||||||||||||||||||||||||||||||||||||
.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
PNP-DB | 0.48 0.03 |
67 17 |
Nanoworld | ▪ Contact cantilever made of silicon nitride ▪ Backside reflective coating (Au) ▪ 2 cantilevers on a chip |
Request for Quote | ||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
NSC36/HARD/AI BS | 1 2 0.6 |
90 130 65 |
Mikromasch | ▪ Contact cantilever ▪ Backside reflective coating (Al) ▪ 3 cantilevers on a chip ▪ Hard Diamond-Like-Carbon coated tip |
Request for Quote | ||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
PNP-DB | 0.48 0.03 |
67 17 |
Nanoworld | ▪ Contact cantilever made of silicon nitride ▪ Backside reflective coating (Au) ▪ 2 cantilevers on a chip |
Request for Quote | ||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
PNP-TR | 0.32 0.08 |
67 17 |
Nanoworld | ▪ Contact cantilever made of silicon nitride ▪ Backside reflective coating (Au) ▪ 2 triangular cantilevers on a chip |
Request for Quote | ||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
PPP-LFMR | 0.2 | 23 | Nanosensors | ▪ Contact cantilever with high sensitivity for lateral/frictional force measurement ▪ Backside reflective coating (Al) |
Request for Quote | ||||||||||||||||||||||||||||||||||||||||||||||
|