The most convenient sample measurements with MultiSample™ scan

Park XE15 MultiSample™ scan system

  • Automated imaging of multiple samples in one pass
  • Specially designed multi-sample chuck for the loading of up to 16 individual samples
  • Fully motorized XY sample stage travels up to 150 mm x 150 mm

Using the motorized sample stage, MultiSample Scan™ enables programmable multiple region imaging in step-and-scan automation.

Here’s how it works:
1. Register multiple scan positions defined by a user
2. Image from the first scan position
3. Lift a cantilever
4. Move the motorized stage to the next user defined coordinate
5. Approach
6. Repeat scan

The registration of multiple scan positions is easily carried out by either entering sample-stage coordinates or sample de-skewing by two reference points. This automated feature greatly increases productivity by reducing the need for your interaction during the scan process.

xe15 afm sys
 

Accurate XY Scan by Crosstalk Elimination

Park Systems’ advanced Crosstalk Elimination (XE) scan system effectively addresses all of the above-mentioned problems. In this configuration, we used a 2-dimensional flexure stage to scan the sample in only the XY direction, and a stacked piezoelectric actuator to scan the probe cantilever in the Z direction only. The flexure stage used for the XY scanner is made of solid aluminum. It demonstrates high orthogonality and an excellent out-of-plane motion profile. The flexure stage can scan large samples (~1 kg) up to a few 100 Hz in the XY direction. This scan speed is sufficient because the bandwidth requirement for the XY axes is much lower than that for the Z axis. The stacked piezoelectric actuator for the Z-scanner has a high resonance frequency (~10 kHz) with a high pushpull force when appropriately pre-loaded.

 

XE scan system

XE-systems
  • independent, loop XY and Z flexure scanners for sample and probe tip

XY flexure scanner

3img 4
  • Flat and orthogonal XY scan with low residual bow
 

XE-Peformence

3img 7

Figure 9. Zero background curvature by Park Systems XE-system (a) and typical background curvature of a conventional AFM system with a tube scanner (b). (c) shows the cross section of these background curvatures.

Figure 9. shows unprocessed AFM images of a bare silicon wafer taken with the XE-system (a), and with a conventional AFM (b). Since the silicon wafer is atomically flat, most of the curvatures in the image are scanner-induced artifacts. Figure 9. (c) shows the cross section of the images in Figure 9. (a) and (b). Since the tube scanner has intrinsic background curvatures, the maximum out-of-plane motion is as much as 80 nm when the X-axis moves 15 μm. The XE scan system has less than 1nm of out-of-plane motion for the same scan range. Another advantage of the XE scan system is its Z-servo response. Figure 10. is an image of a porous polymer sphere (Styrene Divinyl Benzene), whose diameter is about 5 µm, taken with the XE-system in Non-Contact mode. Since the Z-servo response of the XE-system is very accurate, the probe can precisely follow the steep curvature of the polymer sphere as well as small porous surface structures without crashing or sticking to the surface. Figure 11. shows another example that demonstrates the high performance of the z-servo response with a flat background.

3img 83img 9
Figure 10. Figure 11.
 

Better tip life, sample preservation, and accuracy with True Non-Contact™ Mode

In True Non-Contact™ Mode, the tip-sample distance is successfully maintained at a few nanometers in the net attractive regime of inter-atomic force. The small amplitude of tip oscillation minimizes the tip-sample interaction, resulting in superb tip preservation and negligible sample modification.

True Non-Contact™ Mode

non-contact
  • Less tip wear = Prolonged high-resolution scan
  • Non-destructive tip-sample interaction = Minimized sample modification
  • Immunity from parameter dependent results

Tapping Imaging

tapping-imaging
  • Quick tip wear = Blurred low-resolution scan
  • Destructive tip-sample interaction = Sample damage and modification
  • Highly parameter-dependent

Longer Tip Life and Less Sample Damage

The sharp end of an AFM tip is so brittle that once it touches a sample, it becomes instantly blunt and limits the resolution of an AFM and reduces the quality of the image. For softer samples, the tip will damage the sample and also result in inaccuracies of sample height measurements. Consequently, preserving tip integrity enables consistent high resolution and accurate data. True Non-Contact Mode of the XE-AFM superbly preserves the tip, resulting in a much longer tip life and less sample damage. The figure, displayed in 1:1 aspect ratio, shows the unprocessed raw data image of a shallow trench isolation sample imaged by the XE-AFM, whose depth is also confirmed by scanning electron microscope (SEM). The same tip used in the imaging of the sample shows no tip wear even after taking 20 images. xe-afm
 

Park XE15 features

2D Flexure-Guided Scanner with 100 µm x 100 µm Scan Range

2D-Flexure-Guided-Scanner The XY scanner consists of symmetrical 2-dimensional flexure and high-force piezoelectric stacks provides high orthogonal movement with minimal out-of-plane motion as well as high responsiveness essential for precise sample scanning in the nanometer scale.

Flexure-Guided High Force Z Scanner

Driven by a high-force piezoelectric stack and guided by a flexure structure, its rigidity allows it to move at higher speeds in the vertical direction than the scanners used in conventional AFMs. The maximum Z scan range can be extended from 12 µm to 25µm with the optional long range Z scanner (optional).

Slide-to-Connect SLD Head
sld-head

The AFM head is easily inserted or removed by sliding it along a dovetail rail. The low coherency of the Super Luminescence Diode (SLD) enables accurate imaging of highly reflective surfaces and precise measurements for pico-Newton Force-distance spectroscopy. The SLD wavelength eliminates interference issues for users interested in combining the AFM with experiments in the visible spectrum.

Multi-sample Chuck
xe15 afm multisample chuck

The specially designed multi-sample chuck can load up to 16 individual samples, which can be scanned sequentially by MultiSample Scan Automation. The unique head design allows for easy side access to the sample tip.

Motorized XY Sample Stage with Optional Encoders
encoders

The measurement location of the sample is easily and precisely controlled by the integrated motorized XY stage. The travel range of the XY sample stage can be configured for either 150 mm x 150 mm. The encoders, if used with the motorized stages, enable higher positioning repeatability for accurate sample positioning. The encoded XY stage travels in 1 µm resolution with 2 µm repeatability, and the encoded Z stage, in 0.1 µm resolution with 1 µm repeatability

High Resolution Digital CCD Camera with Digital Zoom
Direct on-axis high resolution digital CCD camera with digital zoom capability allows high clarity and high resolution image quality regardless of panning.
Vertically Aligned Motorized Z Stage and Focus Stage
focus-stage

The Z stage and focus stage engage the cantilever with the sample surface while constantly maintaining a clear field of vision for the user. And because the focus stage is motorized and software controlled, it has the precision necessary for transparent samples and liquid cell applications.

Park XE Control Electronics with DSP Board in Controller
1 1 Controller

The nanoscale signals from the AFM are controlled and processed by the high performance Park XE electronics. With its low noise design and high speed processing unit, Park XE electronics successfully realize True Non-Contact™ mode ideal for nanoscale imaging as well as precise voltage and current measurement.

• High performance processing unit of 600 MHz and 4800 MIPS speed
• Low noise design for precise voltage and current measurement
•  Versatile system to utilize various SPM techniques
•  External Signal Access Module to access AFM input/output signals
•  Maximum 16 data images
•  Maximum data size: 4096 × 4096 pixels
•  ADC/DAC in 16 bit, 500 kHz speed
•  Electric noise isolation from PC by TCP/IP connection

 

Experience our product's high-quality, precise, and long life backed by our worldwide service network. We are strongly committed to maintaining the quality of our products, making us a trustworthy choice for all your repair and maintenance needs.